6.2.15 Industry investigation
6.2.15.1 Application
This code applies to development where the code is identified as applicable in a table of assessment.
When using this code, reference should be made to section 5.3.2 and where applicable, section 5.3.3 located in Part 5.
6.2.15.2 Purpose
Note—Future industrial development must be in accordance with an approved structure plan. The Strategic Framework provides further guidance on these matters.
- The purpose of the industry investigation zone code is to identify and protect land that may be suitable for industrial activities in the future. The immediate development of this land is generally inappropriate owing to one or more constraints. These constraints may include a lack of trunk infrastructure necessary to service industrial development and also resolving hydraulic issues in the locality.
- The purpose of the zone will be achieved through the following overall outcomes:
- Land that is suitable for industrial purposes is not developed until necessary trunk infrastructure is provided to the site to service the development.
- Land that is suitable for future industrial purposes is located to minimise impacts on non–industrial land.
- Development does not compromise the future development potential of the area for industrial purposes.
6.2.15.3 Assessment criteria
Table 6.2.15.3.1—Self–assessable and assessable development
Performance outcomes | Acceptable outcomes |
---|---|
Use – Caretaker's accommodation | |
PO1 Development:
|
AO1.1 No more than 1 caretaker's accommodation unit is established on the site. |
AO1.2 The caretaker's accommodation unit is a maximum of 100m2 GFA. |
|
Use – Sales office | |
PO2 The use does not adversely impact on the amenity of the surrounding land uses and local character. |
AO2.1 Development of the sales office is in place for no more than two years. |
AO2.2 There are a maximum of 2 employees on site at any one time. |
|
Building height | |
PO3 Buildings are:
|
AO3 Building height does not exceed 8.5m. |
For all assessable development | |
Uses | |
PO4 Development does not reduce or preclude the long–term use of land within the industry investigation area for industrial purposes. |
No acceptable outcome is nominated. |
Infrastructure | |
PO5 Development is serviced with infrastructure commensurate with its needs. |
No acceptable outcome is nominated. |
Effects of development | |
PO6 Development minimises impacts on non–industrial uses, having regard to:
Note—Applicants may be required to engage specialists to provide detailed investigations into the above matters in order to demonstrate compliance with this performance criterion. |
No acceptable outcome is nominated. |
PO7 Development responds sensitively to on–site and surrounding topography, drainage patterns, coastal foreshores, waterways, utility services, access, vegetation and adjoining land use, such that:
|
No acceptable outcome is nominated. |
Use – Outdoor sport and recreation | |
PO8 All buildings must:
|
No acceptable outcome is nominated. |
PO9 Outdoor lighting does not adversely affect the amenity of adjoining properties or create a traffic hazard on adjacent roads. |
AO9.1 Light emanating from any source complies with Australian Standard AS4282 Control of the Obtrusive Effects of Outdoor Lighting as amended. |
AO9.2 Outdoor lighting is provided in accordance with Australian Standard AS1158.1.1 – Road Lighting – Vehicular Traffic (Category V) Lighting – Performance and Installation Design Requirements as amended. |